1.19533.0500 CYANIDE STANDART SOLUTION MERCK

1.19533.0500 CYANIDE STANDART SOLUTION MERCK

Description Catalogue Number 119533 Product Information HS Code 2837 20 00 Quality Level MQ100 Physicochemical Information Density 1.00 g/cm3 (20 °C) pH value 9 - 10 (H₂O, 20 °C) Safety Information according to GHS Hazard Pictogram(s) Hazard Pictogram(s) Hazard Statement(s) H332: Harmful if inhaled. H412: Harmful to aquatic life with long lasting effects. EUH032: Contact with acids liberates very toxic gas. Precautionary Statement(s) P261: Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray. P271: Use only outdoors or in a well-ventilated area. P273: Avoid release to the environment. P304 + P340 + P312: IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell. P501: Dispose of contents/ container to an approved waste disposal plant. Signal Word Warning Storage class 10 - 13 Other liquids and solids WGK WGK 2 obviously hazardous to water Disposal 6 Sulfides and sulfites as well as other reducing substances, inorganic cyanides and isonitriles: Stir into sodium hypochlorite solution (Cat. No. 105614) and, if necessary, leave to react for several days. Caution: some substances may show a violent reaction! Draw off any toxic or flammable gases that may be formed. Excess oxidant should be neutralized with sodium thiosulfate (Cat. No. 106513). Container D or E. Safety Information Categories of danger harmful Storage and Shipping Information Storage Store at +2°C to +8°C. Transport Information Declaration (railroad and road) ADR, RID Kein Gefahrgut Declaration (transport by air) IATA-DGR No Dangerous Good Declaration (transport by sea) IMDG-Code No Dangerous Good Specifications Concentration     β (CN⁻) 990 - 1010 mg/l Determination method: Argentometric titration. The content of this solution was determined with silver nitrate standard solution (article number 1.09081) standardized against volumetric standard sodium chloride (article number 1.02406). The expanded measurement uncertainty is ± 0.7 % (k=2 coverage factor for 95% coverage probability). The certified value is traceable to primary standard NIST SRM 999c (NIST: National Institute of Standards and Technology, USA) by means of volumetric standard sodium chloride, measured in the accredited calibration laboratory of Merck KGaA, Darmstadt, Germany in accordance to DIN EN ISO/IEC 17025.
Ürün Fiyatı :    ₺
Ürün Kodu :   
Stok Durumu :   VAR
SÜPER HIZLI KARGO HAKKINDA
KARGOM NE ZAMAN ULAŞIR?

HEMEN SİPARİŞ VER!

    ÜRÜN AÇIKLAMASI